Dual Ion Molecule Reaction Mass Spectrometer

TwinSense

The TwinSense is a dual ion-molecule reaction mass spectrometer (IMR-MS) in an analyzer.

The TwinSense dual mass spectrometer is designed to provide fast and simultaneous measurements pre and post catalyst.

Product Photo V&F TwinSense
Product Photo V&F TwinSense
Product Photo V&F TwinSense

Typical applications

  • Development of internal combustion engines (diesel and petrol)
  • Rapid measurement of hydrocarbons
  • Ammonia measurements on DeNOx catalysts
  • NOx measurements on diesel engines
  • Alternative fuels
  • Development of catalysts
  • Desulfurisation measures

Functional diagram

[Translate to EN:] Function Principle V&F Twinsense

Success stories

Measurable compounds

Inorganic compounds
DesignationChemical formula
WaterH2O
OxygenO2
Carbon dioxideCO2
Carbon monoxideCO
Hydrogen sulphideH2S
Sulfur dioxideSO2
SulfurS
AmmoniacNH3
Nitrogen monoxideNO
Nitrogen dioxideNO2
Nitrous oxideN2O
Hydrochloric acidHCl
Aromatics
DesignationChemical formula
BenzeneC6H6
TolueneC7H8
StyreneC8H8
Xylene / EthylbenzeneC8H10
PhenolC6H6O
PAH’s 
Alkanes
DesignationChemical formula
MethaneCH4
EthaneC2H6
PropaneC3H8
ButaneC4H10
PentaneC5H12
HexaneC6H14
HeptaneC7H16
OctaneC8H18
NonaneC9H20
DecaneC10H22
Alkines
DesignationChemical formula
AcetyleneC2H2
PropyneC3H4
Sulfur compounds
Designation Chemical formula
Hydrogen sulfideH2S
Carbonyl sulfideCOS
Sulfur dioxideSO2
Carbon disulfideCS2
Hydrogen sulfideH2S
Methyl mercaptanCH3SH
Ethyl mercaptanC2H5SH
Nitrogen compounds
DesignationChemical formula
AmmoniacNH3
Nitrogen monoxideNO
Nitrogen dioxideNO2
Nitrous oxideN20
Alcohol
DesignationChemical formula
MethanolCH3OH
EthanolC2H5OH
PropanolC3H7OH
ButanolC4H9OH
Aldehydes
DesignationChemical formula
FormaldehydeHCHO
AcetaldehydeCH3CHO
PropionaldehydeC2H5OH
HexanalC6H12O
BenzaldehydeC7H6O

Specifications

Technical Data
Technical DataIMR-MS 1IMR-MS 2
Mass range7 - 519 amu7 - 519 amu
Resolution< 1 amu< 1 amu
Analysis time10 msec10 msec
Measuring range*10^510^5
Response time*T90 < 150 msecT90 < 150 msec
Detection limit*100 ppb100 ppb
Concentration drift‹ ± 5 % over 24 h‹ ± 5 % over 24 h
Accuracy<± 3%<± 3%
Precision<± 3 %<± 3 %
Ambient temperature20 °C - 35 °C20 °C - 35 °C
Max. humidity80 % (non-condensing)80 % (non-condensing)
Gas consumption30 – 3000 ml/min30 – 3000 ml/min
Gas inlet temperature50 °C - 190 °C adjustable50 °C - 190 °C adjustable
Gas inlet pressure0,75 - 2 bar(a)0,75 - 2 bar(a)
Power consumption230 V/50 Hz or 115 V/60 Hz 1.250 W230 V/50 Hz or 115 V/60 Hz 1.250 W
Dimensions (WxHxD)600 x 1,692 x 700 mm600 x 1,692 x 700 mm
Weight208 kg208 kg

 

* depending on the components to be measured, system configuration and unit settings

** depending on the gas inlet system used

Reference clients (excerpt)

Reference APL
Reference BMW
Reference BOSCH
Reference Engelhard
Reference Ford
Reference General Motors
Reference Huber Automotive
Reference Jaguar
Reference Land Rover
Reference Nast
Reference Total
Reference Umicore
Reference Umicore Shokubai
Reference VKA RWTH

Product brochures

For more details, specifications and further information, please refer to our product brochures.

Product brochures
V&F Picture Documents Product Flyer